For the complete documentation index, see llms.txt. This page is also available as Markdown.

SolidSense N8 Compact RS485 and CAN bus

On SolidSense OOB image RS485 and CAN utilities are already built-in

Test CAN bus communication

1. Enable device can0 (for ex):

ip link set can0 up type can bitrate xxxxxx
  • (ex: 125000)

2. Bring the CAN interface up:

ifconfig can0 up

To discover your CAN bus interface name, please run ‘ ip link show ’.

3. To start testing the CanBUS, you have to install the can-utils package by running:

sudo apt-get install -y can-utils 
  • For more information, please follow the CAN-Utils, which are available for Debian/Ubuntu etc

4. Print all data received by CAN interface to “can_test” file (for ex):

candump can0 >> /tmp/can_test &

5. Send data to the bus by executing (for ex):

cansend can0 "123#1234"

6. Check received data by opening “can_test” file:

cat /tmp/can_test

Test RS-485 communication

An example for testing RS485 communication:

1. Open a test file “rs485_test”

3. Print received data to “rs485_test” file:

Last updated