HoneyComb COM 6 Errata

This page outlines the errata for the R8000 / AI 300 COM 6 module

Device fails to Boot after it is powered off and power button is pressed

Symptom

After powering off the device and powering it on using the power button / remote power button, the device fails to boot. In console you will see:

ABL BP[80000000]

Solution

Disconnect power and connect it back to the unit.

Root cause

Unknown


Device fails to boot Memtest86

Symptom

The device will not boot Memtest86 with an error saying: "failed to calibrate CPU frequencies".

Solution

None

Root cause

HPET is disabled in order to allow Linux to boot. (temporary)


USB 2.0 header is not functional

Symptom

The USB 2.0 header is nt functional

Solution

None

Root cause

Work in progress

Last updated