This page outlines the errata for the R8000 / AI 300 COM 6 module
Device fails to Boot after it is powered off and power button is pressed
Symptom
After powering off the device and powering it on using the power button / remote power button, the device fails to boot. In console you will see:
ABL BP[80000000]Solution
Disconnect power and connect it back to the unit.
Root cause
Unknown
Device fails to boot Memtest86
Symptom
The device will not boot Memtest86 with an error saying: "failed to calibrate CPU frequencies".
Solution
HPET is disabled.
Root cause
HPET calibration fails.
USB 2.0 header is not functional
Symptom
The USB 2.0 header is nt functional
Solution
Fixed In BIOS V1.04, users who experience this issue are recommended to update.
Root cause
Work in progress
Last updated